Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Methods Mol Biol ; 1913: 33-48, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30666597

RESUMO

As therapies involving the modulation, stimulation, and deliberate excitation of the immune system are becoming routine, better methods for monitoring immune responses in human patients are needed. Mass cytometry allows for detailed profiling of all immune cell populations and their functional responses using a simple blood sample. When combined with appropriate computational analyses, the resolution for distinguishing desired responses from unproductive or even adverse reactions to immunotherapeutic interventions increases. Here we describe a core experimental and computational framework for global, systems-level immune monitoring by mass cytometry.


Assuntos
Receptores Coestimuladores e Inibidores de Linfócitos T/imunologia , Citometria de Fluxo/métodos , Monitorização Imunológica/métodos , Neoplasias/imunologia , Análise de Célula Única/métodos , Antineoplásicos Imunológicos/farmacologia , Antineoplásicos Imunológicos/uso terapêutico , Receptores Coestimuladores e Inibidores de Linfócitos T/antagonistas & inibidores , Citometria de Fluxo/instrumentação , Humanos , Sistema Imunitário/efeitos dos fármacos , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/imunologia , Monitorização Imunológica/instrumentação , Neoplasias/sangue , Neoplasias/tratamento farmacológico , Análise de Célula Única/instrumentação , Resultado do Tratamento
2.
Methods Mol Biol ; 1913: 49-65, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30666598

RESUMO

The irruption of immune-activating therapies to treat cancer has created a need for evaluating both the response and possible adverse events related to these novel treatments. Multicolor flow cytometry is a powerful tool that enables tumor immunologists to characterize the immune system of patients before and in response to immunotherapy. We present here a protocol for purifying human peripheral blood mononuclear cells and staining them with a set of six multicolor panels that allow for a thorough characterization of the immune system of healthy donors as well as patients that are undergoing treatments that may modify the immune system.


Assuntos
Citometria de Fluxo/métodos , Monitorização Imunológica/métodos , Neoplasias/imunologia , Coloração e Rotulagem/métodos , Antineoplásicos Imunológicos/farmacologia , Antineoplásicos Imunológicos/uso terapêutico , Centrifugação com Gradiente de Concentração/instrumentação , Centrifugação com Gradiente de Concentração/métodos , Cor , Citometria de Fluxo/instrumentação , Humanos , Sistema Imunitário/efeitos dos fármacos , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/imunologia , Monitorização Imunológica/instrumentação , Neoplasias/sangue , Neoplasias/tratamento farmacológico , Coloração e Rotulagem/instrumentação , Resultado do Tratamento
3.
Einstein (Sao Paulo) ; 16(4): eAO4278, 2018 Nov 29.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30517367

RESUMO

OBJECTIVE: To investigate the correlation between total lymphocyte and CD3+ T cell counts in peripheral blood in renal transplant patients treated with anti-thymocyte globulin, and discuss related outcomes. METHODS: A single-center, retrospective study involving 226 patients submitted to kidney transplant between 2008 and 2013, and treated with anti-thymocyte globulin for induction or treatment of cellular rejection. Doses were adjusted according to CD3+ T cell or total lymphocyte counts in peripheral blood. RESULTS: A total of 664 paired samples were analyzed. The Spearman's correlation coefficient was 0.416 (p<0.001) for all samples combined; the overall Kappa coefficient was 0.267 (p<0.001). Diagnostic parameters estimated based on total lymphocyte counts were also calculated using the number of CD3+ T cells (gold standard), with a cut off of >20 cells/mm3. CONCLUSION: Total lymphocyte and CD3+ T cell counts in peripheral blood are not equivalent monitoring strategies in anti-thymocyte globulin therapy.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Complexo CD3 , Rejeição de Enxerto/terapia , Isoanticorpos/uso terapêutico , Transplante de Rim , Timócitos/imunologia , Transplantados , Adulto , Feminino , Citometria de Fluxo/métodos , Humanos , Imunoterapia/métodos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/instrumentação , Estudos Retrospectivos , Análise de Sobrevida , Linfócitos T/imunologia
4.
J Clin Microbiol ; 56(4)2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29305542

RESUMO

The clinical utility of the QuantiFERON-CMV (QFN-CMV) assay in heart transplant recipients was assessed. Forty-four cytomegalovirus (CMV)-seropositive patients were enrolled: 17 received antiviral prophylaxis, and 27 were managed preemptively. CMV-DNAemia monitoring was performed by the use of a quantitative real-time PCR assay. The QFN-CMV assay was retrospectively performed on blood samples collected at five posttransplant time points. A higher proportion of patients with an indeterminate QFN-CMV result after the suspension of prophylaxis than of patients who showed a global T-cell responsiveness developed CMV infection (P = 0.036). Patients who reconstituted a CMV-specific response following the first CMV-DNAemia-positive result (42.9%) showed a median CMV-DNAemia peak 1 log of magnitude lower than that seen with patients with indeterminate results, and all controlled viral replication spontaneously. The 25% of patients with an indeterminate result developed CMV disease. In the preemptive strategy group, no differences in the development of subsequent infection, magnitude of viral load, and viral control were observed on the basis of QFN-CMV measurements performed before and after the first CMV-DNAemia-positive result. Considering both CMV prevention strategies, viral relapse was associated with the failure to reconstitute CMV-specific cell-mediated immunity (CMI) after the resolution of the first episode of CMV infection (P = 0.032). QFN-CMV measurements can be a useful tool for identifying patients (i) at higher risk of developing infection after discontinuing antiviral prophylaxis, (ii) with late CMV infection who would benefit from appropriate antiviral interventions, and (iii) at higher risk of viral relapses. QFN-CMV measurements taken within 1 month posttransplantation (early period) are not revealing.


Assuntos
Infecções por Citomegalovirus/imunologia , Citomegalovirus/imunologia , DNA Viral/sangue , Transplante de Coração/efeitos adversos , Imunidade Celular , Monitorização Imunológica/métodos , Adulto , Idoso , Antivirais/administração & dosagem , Antivirais/uso terapêutico , Citomegalovirus/genética , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/epidemiologia , Infecções por Citomegalovirus/prevenção & controle , DNA Viral/genética , DNA Viral/isolamento & purificação , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Estudos Retrospectivos , Transplantados , Valganciclovir/administração & dosagem , Valganciclovir/uso terapêutico , Carga Viral , Viremia , Adulto Jovem
5.
Einstein (Säo Paulo) ; 16(4): eAO4278, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975101

RESUMO

ABSTRACT Objective: To investigate the correlation between total lymphocyte and CD3+ T cell counts in peripheral blood in renal transplant patients treated with anti-thymocyte globulin, and discuss related outcomes. Methods: A single-center, retrospective study involving 226 patients submitted to kidney transplant between 2008 and 2013, and treated with anti-thymocyte globulin for induction or treatment of cellular rejection. Doses were adjusted according to CD3+ T cell or total lymphocyte counts in peripheral blood. Results: A total of 664 paired samples were analyzed. The Spearman's correlation coefficient was 0.416 (p<0.001) for all samples combined; the overall Kappa coefficient was 0.267 (p<0.001). Diagnostic parameters estimated based on total lymphocyte counts were also calculated using the number of CD3+ T cells (gold standard), with a cut off of >20 cells/mm3. Conclusion: Total lymphocyte and CD3+ T cell counts in peripheral blood are not equivalent monitoring strategies in anti-thymocyte globulin therapy.


RESUMO Objetivo: Investigar a correlação entre a contagem de linfócitos totais e células T CD3+ no sangue periférico em receptores de transplante renal submetidos a tratamento com globulina antitimocitária, e discutir resultados relacionados. Métodos: Estudo retrospectivo de centro único envolvendo 226 pacientes submetidos a transplante renal entre 2008 e 2013 e tratados com globulina antitimocitária, para fins de indução ou tratamento de rejeição celular. As doses foram ajustadas de acordo com a contagem de células T CD3+ ou linfócitos totais no sangue periférico. Resultados: No total, 664 amostras pareadas foram analisadas. O coeficiente de correlação de Spearman para as amostras em geral foi de 0,416 (p<0,001) e o coeficiente Kappa, de 0,267 (p<0,001). Os parâmetros diagnósticos estimados com base na contagem de linfócitos totais foram recalculados, empregando-se o número de células T CD3+ (padrão-ouro) e adotando-se o ponto de corte >20 células/mm3. Conclusão: A contagem de linfócitos totais no sangue periférico não substitui a contagem de células T CD3+ enquanto estratégia de monitorização da terapia à base de globulina antitimocitária.


Assuntos
Humanos , Masculino , Feminino , Adulto , Transplante de Rim , Complexo CD3 , Timócitos/imunologia , Transplantados , Rejeição de Enxerto/terapia , Isoanticorpos/uso terapêutico , Anticorpos Monoclonais/uso terapêutico , Linfócitos T/imunologia , Monitorização Imunológica/instrumentação , Análise de Sobrevida , Estudos Retrospectivos , Contagem de Linfócitos , Citometria de Fluxo/métodos , Imunoterapia/métodos , Pessoa de Meia-Idade
6.
Allergol. immunopatol ; 44(4): 322-330, jul.-ago. 2016. graf, tab
Artigo em Inglês | IBECS | ID: ibc-154434

RESUMO

PURPOSE: The aim was to describe the clinical manifestations, complications and long-term outcome of a cohort of Iranian patients with primary immune deficiency (PID). METHOD: We retrospectively studied the demographic, clinical and immunological characteristics of the PID patients in a single tertiary centre, from January 1989 to July 2014. The patients were classified according to the International Union of Immunological Societies Expert Committee on PID. RESULTS: 98 patients were diagnosed with and followed-up for 15 disorders. The mean age at onset and diagnosis and the diagnostic delay were 8±10, 14.2±13.1 and 6.1±7 years, respectively. Parental consanguinity rate was 57%. Predominantly Antibody Deficiency was the most common diagnosis (n=63), followed by congenital defects of phagocytes (n=16), combined immunodeficiencies (n=12), well defined syndromes (n=4) and defects in innate immunity (n=3). Recurrent sinopulmonary infection was the most common presentation. Active infections were treated appropriately, in addition to prophylactic therapy with IVIG and antimicrobials. Not all the patients were compliant with prophylactic regimens due to cost and unavailability. One SCID patient underwent successful bone marrow transplantation. The total mortality rate was 19% during the follow-up period (7.8±7.6 years). The mean age of living patients at the time of study was 23±11.7 years. CONCLUSIONS: Physicians awareness of PID has been rising dramatically in Iran, ensuring an increasing number of patients being diagnosed and treated. More effective treatment services, including health insurance coverage and drug availability are needed to improve the outcome of PID patients


No disponible


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Síndromes de Imunodeficiência/diagnóstico , Síndromes de Imunodeficiência/imunologia , Síndromes de Imunodeficiência/patologia , Vigilância Imunológica , Vigilância Imunológica/imunologia , Monitorização Imunológica/instrumentação , Monitorização Imunológica/métodos , Dessensibilização Imunológica , Testes Laboratoriais/métodos , Imunoglobulina G/análise , Imunoglobulina G/imunologia , Estudos de Coortes , Imunocompetência/imunologia
7.
PLoS One ; 11(5): e0154000, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27166955

RESUMO

BACKGROUND: HIV infection is a concern in the army troupes because of the risk behaviour of the military population. In order to allow regular access to CD4+ T cell enumeration of military personnel as well as their dependents and civilians living with HIV, the Senegalese Army AIDS program is implementing PIMATM Alere technology in urban and semi-urban military medical centres. Validation such device is therefore required prior their wide implementation. The purpose of this study was to compare CD4+ T cell count measurements between the PIMATM Alere to the BD FACSCountTM. METHODOLOGY: We selected a total of 200 subjects including 50 patients with CD4+ T-cells below 200/mm3, 50 between 200 and 350/mm3, 50 between 351 and 500/mm3, and 50 above 500/mm3. CD4+ T-cell count was performed on venous blood using the BD FASCountTM as reference method and the PIMATM Point of Care technology. The mean biases and limits of agreement between the PIMATM Alere and BD FACSCountTM were assessed with the Bland-Altman analysis, the linear regression performed using the Passing-Bablok regression analysis, and the percent similarity calculated using the Scott method. RESULTS: Our data have shown a mean difference of 22.3 cells/mm3 [95%CI:9.1-35.5] between the BD FACSCountTM and PIMATM Alere CD4 measurements. However, the mean differences of the two methods was not significantly different to zero when CD4+ T-cell count was below 350/mm3 (P = 0.76). The Passing-Bablok regression in categorized CD4 counts has also showed concordance correlation coefficient of 0.89 for CD4+ T cell counts below 350/mm3 whilst it was 0.5 when CD4 was above 350/mm3. CONCLUSION: Overall, our data have shown that for low CD4 counts, the results from the PIMATM Alere provided accurate CD4+ T cell counts with a good agreement compared to the FACSCountTM.


Assuntos
Contagem de Linfócito CD4/instrumentação , Infecções por HIV/diagnóstico , Infecções por HIV/imunologia , Militares , Monitorização Imunológica/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito/normas , Adulto , Idoso , Contagem de Linfócito CD4/métodos , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/virologia , Feminino , Citometria de Fluxo , Infecções por HIV/prevenção & controle , Infecções por HIV/virologia , Hospitais Militares/organização & administração , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/métodos , Sistemas Automatizados de Assistência Junto ao Leito/organização & administração , Assunção de Riscos , Comportamento Sexual/psicologia
8.
Arch. bronconeumol. (Ed. impr.) ; 52(1): 29-35, ene. 2016. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-147917

RESUMO

La enfermedad pulmonar obstructiva crónica (EPOC) y el cáncer de pulmón (CP) son enfermedades prevalentes y representan causas principales de morbimortalidad a nivel global. Existe firme evidencia que demuestra que la EPOC es un factor de riesgo independiente de CP. La inflamación crónica juega un rol patogénico significativo en el desarrollo de las comorbilidades en la EPOC, y en particular en el CP. Diferentes mediadores inflamatorios celulares y moleculares promueven la tumorigénesis e inhiben la capacidad del sistema inmunitario de reconocer y eliminar células premalignas y malignas, proceso conocido como inmunovigilancia tumoral. Esta alteración de la inmunidad antitumoral se debe en parte a la expansión de las células mieloides supresoras (myeloid derived suppressor cells [MDSC]), que se caracterizan por suprimir la función efectora antitumoral de linfocitosT mediante la reducción de la expresión del T-cell receptor ζ (TCRζ) a través del catabolismo de la L-arginina. Los pacientes con EPOC y CP comparten un patrón similar de aumento y activación de las MDSC circulantes asociado a la reducción de la expresión del TCRζ y a la alteración de la función de los linfocitosT periféricos. Los objetivos de este artículo son revisar la evidencia sobre la asociación entre EPOC y CP, y analizar cómo la acumulación de MDSC podría alterar la inmunovigilancia tumoral en la EPOC y favorecer el desarrollo de CP


Chronic obstructive pulmonary disease (COPD) and lung cancer (LC) are prevalent diseases and are a leading cause of morbidity and mortality worldwide. There is strong evidence to show that COPD is an independent risk factor for LC. Chronic inflammation plays a significant pathogenic role in COPD comorbidities, particularly in LC. On the one hand, cellular and molecular inflammatory mediators promote carcinogenesis and, on the other, chronic inflammation impairs the capacity of the immune system to identify and destroy pre-malignant and malignant cells, a process known as tumor immune surveillance. This altered antitumor immunity is due in part to the expansion of myeloid-derived suppressor cells (MDSC), which are characterized by an ability to suppress the antitumor activity of T-cells by down-regulation of the T-cell receptor ζ chain (TCRζ) through the catabolism of L-arginine. COPD and LC patients share a common pattern of expansion and activation of circulating MDSC associated with TCRζ downregulation and impaired peripheral T-cell function. The objectives of this study were to review the evidence on the association between COPD and LC and to analyze how MDSC accumulation may alter tumor immune surveillance in COPD, and therefore, promote LC development


Assuntos
Humanos , Masculino , Feminino , Células Mieloides/imunologia , Células Mieloides , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/imunologia , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/imunologia , Anticorpos Antineoplásicos/imunologia , Arginase/imunologia , Arginase/isolamento & purificação , Indicadores de Morbimortalidade , Mediadores da Inflamação , Mediadores da Inflamação/imunologia , Mediadores da Inflamação/isolamento & purificação , Monitorização Imunológica/instrumentação , Monitorização Imunológica/métodos , Monitorização Imunológica
10.
Transplantation ; 99(8): 1625-32, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25757214

RESUMO

BACKGROUND: An immune function assay shows promise for identifying solid organ recipients at risk for infection or rejection. The following randomized prospective study was designed to assess the clinical benefits of adjusting immunosuppressive therapy in liver recipients based on immune function assay results. METHODS: Adult liver recipients were randomized to standard practice (control group; n = 102) or serial immune function testing (interventional group; n = 100) performed with a commercially available in vitro diagnostic assay (ImmuKnow; Viracor-IBT Laboratories, Lee's Summit, MO) before transplantation, immediately after surgery and at day 1, weeks 1 to 4, 6, and 8, and months 3 to 6, 9, and 12. The assay was repeated within 7 days of suspected/confirmed rejection/infection and within 1 week after event resolution. RESULTS: Based on immune function values, tacrolimus doses were reduced 25% when values were less than 130 ng/mL adenosine triphosphate (low immune cell response) and increased 25% when values were greater than 450 ng/mL adenosine triphosphate (strong immune cell response). The 1-year patient survival was significantly higher in the interventional arm (95% vs 82%; P < 0.01) and the incidence of infections longer than 14 days after transplantation was significantly lower among patients in the interventional arm (42.0% vs. 54.9%, P < 0.05). The difference in infection rates was because of lower bacterial (32% vs 46%; P < 0.05) and fungal infection (2% vs 11%; P < 0.05). Among recipients without adverse events, the study group had lower tacrolimus dosages and blood levels. CONCLUSIONS: Immune function testing provided additional data which helped optimize immunosuppression and improve patient outcomes.


Assuntos
Monitoramento de Medicamentos/métodos , Rejeição de Enxerto/prevenção & controle , Imunossupressores/administração & dosagem , Transplante de Fígado , Monitorização Imunológica/métodos , Tacrolimo/administração & dosagem , Trifosfato de Adenosina/sangue , Adulto , Idoso , Biomarcadores/sangue , Cálculos da Dosagem de Medicamento , Monitoramento de Medicamentos/instrumentação , Quimioterapia Combinada , Feminino , Rejeição de Enxerto/sangue , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/mortalidade , Sobrevivência de Enxerto/efeitos dos fármacos , Humanos , Hospedeiro Imunocomprometido , Imunossupressores/efeitos adversos , Imunossupressores/sangue , Imunossupressores/farmacocinética , Itália , Transplante de Fígado/efeitos adversos , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/instrumentação , Infecções Oportunistas/imunologia , Infecções Oportunistas/prevenção & controle , Valor Preditivo dos Testes , Estudos Prospectivos , Kit de Reagentes para Diagnóstico , Esteroides/administração & dosagem , Tacrolimo/efeitos adversos , Tacrolimo/sangue , Tacrolimo/farmacocinética , Resultado do Tratamento
12.
Biosens Bioelectron ; 61: 152-64, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24874659

RESUMO

The field of nanotechnology has recently seen vast advancements in its applications for therapeutic strategy. This technological revolution has led way to nanomedicine, which spurred the development of clever drug delivery designs and ingenious nanovehicles for the monitoring of cellular events in vivo. The clinical implementations of this technology are innumerable and have demonstrated utility as diagnostic tools and fortifying machineries for the mammalian immune system. Recently engineered viral vectors and multi-subunit packaging RNAs have verified stable enough for long-term existence in the physiological environment and therefore reveal unique potential as artificial immunosurveillance devices. Physiological and pathological events recorded by nanodevices could help develop "biocatalogs" of patients' infection history, frequency of disease, and much more. In this article, we introduce a novel design concept for a multilayer synthetic immune network parallel to the natural immune system; an artificial network of continuously patrolling nanodevices incorporated in the blood and lymphatic systems, and adapted for molecular event recording, anomaly detection, drug delivery, and gene silencing. We also aim to discuss the approaches and advances recently reported in nanomedicine, especially as it pertains to promising viral and RNA-based nanovehicles and their prospective applications for the development of a synthetic immunosurveillance system (SIS). Alternative suggestions and limitations of these technologies are also discussed.


Assuntos
Técnicas Biossensoriais/métodos , Sistemas de Liberação de Medicamentos/métodos , Monitorização Imunológica/métodos , Nanomedicina/métodos , Animais , Técnicas Biossensoriais/instrumentação , Sistemas de Liberação de Medicamentos/instrumentação , Engenharia Genética/instrumentação , Engenharia Genética/métodos , Vetores Genéticos/química , Vetores Genéticos/genética , Humanos , Modelos Moleculares , Monitorização Imunológica/instrumentação , Nanomedicina/instrumentação , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Vírus/química , Vírus/genética
13.
Int Arch Allergy Immunol ; 163(1): 59-68, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24248100

RESUMO

BACKGROUND: Patients with allergic rhinoconjunctivitis are susceptible to both nasal and ocular symptoms. The conjunctival provocation test (CPT) is an established diagnostic procedure used in allergic rhinoconjunctivitis, particularly to document a patient's current reactivity to allergens. To date, there are no international guidelines defining the CPT. No approved evaluation method exists for interpreting CPT results. This paper aims to establish the digital analysis of macroimages as an objective, validated and standardized method for interpreting CPT results. METHODS: In a clinical immunotherapy trial with 155 patients, treatment progress was documented based on the CPT. Local investigators used a symptom score to grade tearing, reddening and the patients' subjective perception of symptoms (mucosal irritation). A central observer rated conjunctival hyperemia via digital photography. Digital image analysis software was utilized to determine conjunctival hyperemia. RESULTS: Spearman's correlation between the local investigators' and the central observer's ratings was r = 0.729 (p < 0.001); the percentage of total agreement was 48% (based on 739 photos). Digital image analysis (based on 48 photos) had a high percentage of total agreement with the central observer's ratings (69%) but a low percentage of total agreement with the investigators' ratings (38%). The corresponding correlations were r = 0.264 and 0.064, respectively. CONCLUSION: Photography-based rating by a central observer may represent a valuable supplement to the local investigator's assessment for making an objective evaluation of CPT results. Digital image analysis possesses the potential of being an objective evaluation method compared to the wide-spread subjective evaluation by the investigators.


Assuntos
Conjuntivite Alérgica/diagnóstico , Monitorização Imunológica/instrumentação , Rinite Alérgica Sazonal/diagnóstico , Adulto , Alérgenos/administração & dosagem , Alérgenos/imunologia , Ensaios Clínicos como Assunto , Misturas Complexas/administração & dosagem , Misturas Complexas/imunologia , Conjuntivite Alérgica/complicações , Conjuntivite Alérgica/imunologia , Conjuntivite Alérgica/terapia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imunoterapia/métodos , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/normas , Fotografação/instrumentação , Pólen/química , Análise de Regressão , Rinite Alérgica Sazonal/complicações , Rinite Alérgica Sazonal/imunologia , Rinite Alérgica Sazonal/terapia , Índice de Gravidade de Doença
14.
Arch Immunol Ther Exp (Warsz) ; 61(5): 421-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23934041

RESUMO

The changes in the number of CD8⁺ T lymphocytes were studied before (0 day) and then 30 days after the autologous hematopoietic stem cell transplantations (AHSCT) in 14 therapy refractory patients with autoimmune diseases. The years of survival and the clinical states were also evaluated. The number of CD8⁺ T cells was determined by an hematologic automat and by flow cytometry. Longer than 5-year survival times were found in 6 cases, whereas there was no progression (improvement) in 2 cases, and 4 patients were lost. The increase in the number of CD8⁺ cytotoxic T cells was gradual in the first 2 months and reached the significantly highest values among all subtypes of lymphocytes. It was of a special interest that in all the 4 patients who died, the numbers of CD8⁺ T cells were less than 150/µl on the 30th day after AHSCT, whereas all the 10 patients with a higher cell number survived. These results suggest that the early monitoring of the number (not only the ratio) of regenerating CD8⁺ T cells in the peripheral blood can be a useful and quantitative laboratory measurement after AHSCT, and it has a significant relation also to the survival times of transplanted patients.


Assuntos
Doenças Autoimunes/diagnóstico , Doenças Autoimunes/imunologia , Células Sanguíneas/imunologia , Linfócitos T CD8-Positivos/imunologia , Transplante de Células-Tronco Hematopoéticas , Monitorização Imunológica/métodos , Adulto , Doenças Autoimunes/mortalidade , Doenças Autoimunes/terapia , Separação Celular , Feminino , Citometria de Fluxo , Seguimentos , Humanos , Contagem de Linfócitos/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Monitorização Imunológica/instrumentação , Prognóstico , Recidiva , Análise de Sobrevida , Transplante Autólogo
16.
Cytometry B Clin Cytom ; 76(2): 118-26, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18825776

RESUMO

BACKGROUND: We developed a volumetric single platform image cytometer (SP ICM) that is dedicated to count CD4(+) and CD8(+) T lymphocytes for HIV monitoring in resource-constrained settings. The instrument was designed to be low-cost, yet reliable, easy-to-use, and robust. METHODS: Whole blood is incubated with CD3-magnetic nanoparticles, CD4-phycoerythrin (PE), and CD8-peridinin-chlorophyll-protein complex (PerCP). The CD3 cells are immunomagnetically attracted to an analysis surface, where fluorescence images of CD4(+) and CD8(+) T lymphocytes are recorded and analyzed, respectively. We compared CD4, CD8 counts, and CD4/CD8 ratio obtained by the SP ICM with those from a SP flow cytometer (FCM) tetraCXP method on blood samples from 145 patients. RESULTS: Good correlations were obtained (R: 0.96-0.99) between the SP ICM and the SP FCM. There was approximately 10% CD8 undercount in the SP ICM, which could be partly caused by CD8(+dim) T lymphocytes that were not detected by the instrument or not counted by the image analysis due to the cross-talk from the CD4-PE signal in the CD8-PerCP image. CONCLUSIONS: The SP ICM is a good candidate for HIV monitoring in point-of-care settings of resource-constrained countries.


Assuntos
Contagem de Linfócito CD4/métodos , Relação CD4-CD8/métodos , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Citometria por Imagem/métodos , Monitorização Imunológica/métodos , Antígenos CD4/análise , Antígenos CD4/metabolismo , Antígenos CD8/análise , Antígenos CD8/metabolismo , Citometria de Fluxo/economia , Citometria de Fluxo/métodos , Corantes Fluorescentes , Infecções por HIV/imunologia , Humanos , Citometria por Imagem/economia , Citometria por Imagem/instrumentação , Separação Imunomagnética/economia , Separação Imunomagnética/instrumentação , Separação Imunomagnética/métodos , Microscopia de Fluorescência/métodos , Monitorização Imunológica/economia , Monitorização Imunológica/instrumentação , Valor Preditivo dos Testes , Linfócitos T/imunologia , Linfócitos T/virologia
17.
Liver Transpl ; 14(6): 893-8, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18508374

RESUMO

Lifelong immunosuppression is mandatory for optimal graft and patient survival following liver transplantation. Nevertheless, graft rejection or numerous adverse events associated with overimmunosuppression or underimmunosuppression cannot be completely avoided. The ImmuKnow assay measures cell-mediated immunity and is able to discern between conditions of overimmunosuppression and underimmunosuppression. The aim of this study was to evaluate the ImmuKnow assay in the evaluation of the immune function in pediatric liver transplant recipients and to assess its correlation with the patients' clinical and biochemical status. Eighty-nine whole blood samples were collected from 23 liver transplant recipients that were 1 to 18 years old. The net state of immune function was determined by the quantitative measurement of the intracellular adenosine 5-triphosphate level in CD4+ lymphocytes after phytohemagglutinin stimulation. Comprehensive clinical data were correlated with the ImmuKnow assay results. In 23 of the 28 samples collected during clinical quiescence, ImmuKnow results were correlated with the clinical status, expressing the patient's moderate immune function. However, a correlation between measured therapeutic drug levels and clinical quiescence was found in only 18 of the 28 samples. In 6 patients who suffered from clinical complications, ImmuKnow measurements showed a wide range of deviations, expressing the unstable immunological status of these patients. In conclusion, the ImmuKnow assay correlates with the clinical status of liver-transplanted children. It serves as a reliable and unique parameter of the cellular immune function. We conclude that the ImmuKnow assay, together with existing clinical tools, may allow for the immune monitoring of pediatric liver recipients.


Assuntos
Gastroenterologia/métodos , Hepatopatias/imunologia , Hepatopatias/terapia , Transplante de Fígado/métodos , Monitorização Imunológica/instrumentação , Monitorização Imunológica/métodos , Criança , Pré-Escolar , Feminino , Gastroenterologia/instrumentação , Rejeição de Enxerto , Humanos , Imunossupressores/uso terapêutico , Lactente , Recém-Nascido , Hepatopatias/sangue , Masculino , Modelos Biológicos , Projetos Piloto
18.
Life Sci ; 79(14): 1317-33, 2006 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-16757003

RESUMO

The dynamics of how astronauts' immune systems respond to space flight have been studied extensively, but the complex process has not to date been thoroughly characterized, nor have the underlying principles of what causes the immune system to change in microgravity been fully determined. Statistically significant results regarding overall immunological effects in space have not yet been established due to the relatively limited amount of experimental data available, and are further complicated by the findings not showing systematically reproducible trends. Collecting in vivo data during flight without affecting the system being measured would increase understanding of the immune response process. The aims of this paper are to briefly review the current knowledge regarding how the immune system is altered in space flight; to present a group of candidate biomarkers that could be useful for in-flight monitoring and give an overview of the current methods used to measure these markers; and finally, to further establish the need and usefulness of incorporating real-time analytical techniques for in-flight assessment of astronaut health, emphasizing the potential application of MEMS/NEMS devices.


Assuntos
Imunidade/fisiologia , Monitorização Imunológica/instrumentação , Nanotecnologia , Voo Espacial , Animais , Biomarcadores , Células Cultivadas , Citocinas/sangue , Humanos , Ausência de Peso/efeitos adversos , Simulação de Ausência de Peso
19.
Semin Oncol ; 30(3 Suppl 8): 9-16, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12881807

RESUMO

While the future of immunotherapy in the treatment of cancer is promising, it is difficult to compare the various approaches because monitoring assays have not been standardized in approach or technique. Common assays for measuring the immune response need to be established so that these assays can one day serve as surrogate markers for clinical response. Assays that accurately detect and quantitate T-cell-mediated, antigen-specific immune responses are particularly desired. However, to date, increases in the number of cytotoxic T cells through immunization have not been correlated with clinical tumor regression. Ideally, then, a T-cell assay not only needs to be sensitive, specific, reliable, reproducible, simple, and quick to perform, it must also demonstrate close correlation with clinical outcome. Assays currently used to measure T-cell response are delayed-type hypersensitivity testing, flow cytometry using peptide major histocompatibility complex tetramers, lymphoproliferation assay, enzyme-linked immunosorbant assay, enzyme-linked immunospot assay, cytokine flow cytometry, direct cytotoxicity assay, measurement of cytokine mRNA by quantitative reverse transcriptase polymerase chain reaction, and limiting dilution analysis. The purpose of this review is to describe the attributes of each test and compare their advantages and disadvantages.


Assuntos
Vacinas Anticâncer/farmacologia , Imunidade Celular/efeitos dos fármacos , Imunoterapia Ativa , Monitorização Imunológica , Neoplasias/imunologia , Neoplasias/terapia , Humanos , Monitorização Imunológica/instrumentação , Monitorização Imunológica/mortalidade
20.
Biomed Tech (Berl) ; 47 Suppl 1 Pt 1: 213-6, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12451820

RESUMO

We report on the development of an innovative electro-magnetic base technology for estremely sensitive sensors allowing the electrical detection of biological analytes like antigenes or DNA as well as a simple multiple detection of binding forces occurring at specific bonds between proteins. The technology is based on the strong impact of specifically captured magnetic microbeads on an electrical current generated in a fluid by a small sensor chip with an array of activated microelectrodes. The new technological principle with the on-chip detection of analytes will be suitable for large scale applications due to its mass production compatible technologies and allow an alternative way to monitor relevant substances without the consumption of critical additional solutions and reagents.


Assuntos
Microeletrodos , Monitorização Imunológica/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Campos Eletromagnéticos , Desenho de Equipamento , Humanos , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...